第11回
Image Enhancement for Concrete Bridge Inspection with Portable 950 keV/ 3.95 MeV X-ray Source
著者:
Cuixiang Pei, Mitsuru Ueaska, Wenjing Wu , Katsuhiro Dobashi, Takeshi Fujiwara, Jyoichi, Jyoichi Kusano, Naoki Nakamura, and Yositomi Kimura
発刊日:
公開日:
キーワードタグ:
Abstract: The use of portable and high-energy x-ray system can provide a very promising approach for the inspection of aged concrete structures. However, due to the effect of large scattering of low-energy x-ray in a thick concrete, the noise properties and contrast of the radiographic images need to be optimized to ensure reliable interpretation. Therefore, in order to improve the inspection ability, an image denoising method with the combination of wavelet and curvelet transform and image contrast e...
英字タイトル:
Image Enhancement for Concrete Bridge Inspection with Portable 950 keV/ 3.95 MeV X-ray Source
第9回
On-Site Bridge Inspection with Partial CT by 3.95Mev X-Band Linac Source
著者:
WU Wenjing,ZHU Haito,JIN Ming,Katsuhiro DOBASHI,Takeshi FUJIWARA,Mitsuru UESAKA,Jyuichi KUSANO,Naoki NAKAMURA,Eiji TANABE,Hideyuki SUNAGA,Yoshie OHTAKE
発刊日:
公開日:
キーワードタグ:
Abstract: Since more and more bridges built several decades ago in Japan have become aged and dangerous, the non-destructive evaluation of those bridges is really an urgent problem. CT system with portable 3.95MeV linacs for bridge inspection is considered to work on-site, considering the law of Japanese radiation protection allows using linacs up to 4MeV outside radiation controlled area. The system would confirm the internal steel si tuation of bridges and analyze structural strain and stress with 3D mod...
英字タイトル:
On-Site Bridge Inspection with Partial CT by 3.95Mev X-Band Linac Source
第10回
Partial Inspection and Dual-energy CT Material Analysis with 950keV/3.95MeV X-Band Linac
著者:
Wenjing WU,Haito ZHU,Ming JIN,Katsuhiro DOBASHI ,Takeshi FUJIWARA,Mitsuru UESAKA,Joichi KUSANO,Naoki NAKAMURA ,Eiji TANABE ,Hideyuki SUNAGA ,Yoshie OTAKE
発刊日:
公開日:
キーワードタグ:
In situ CT application for NDE of degradation bridges is under development, with portable 950keV/3.95 MeV X-band linac as x-ray source. Collimator is adopted to reduce scattered X-ray noise. Material analysis and erosion estimation through dl-energy CT method is integrated in order to inspect the erosion situation of i nner steel rod. Reconstruction technique with incomplete projection data is studd considering limitation of projection angle range during onsite scanning. Furt hermore, based on 3D model bui...
英字タイトル:
Partial Inspection and Dual-energy CT Material Analysis with 950keV/3.95MeV X-Band Linac